Resideo


2271 products

Resideo

R8182H1070

Combination Protectorelay and Hydronic Heating Controller, 120Vac, 45 Second Safety Switch Timing, 130-240 Degree High Limit Operating Range, 110-220 Degree Low Limit Operating Range, 10 Degree Fixed High Limit Differential, 10-25 Degree Adjustable Low Limit or Circulator, 1 1/2" Insulation Depth, Junction Box Mount, 4.4 Amp @ 120Vac Full Load Electrical Rating, 26.4 Amp @ 120Vac Locked Rotar Electrical Rating, Includes Auxiliary ZC and ZR Terminals that may be used to provide Circulator Zone Control through an R845A, Also Includes Heat Conductive Compound and Vertical Case

Resideo

R8184G4009

Protectorelay Oil Burner Control, Controls Oil Burner, Oil Valve and the Ignition Transformer in Response to a Call for Heat, 45 Second Safety Switch Timing, With LED for Lockout Indication and Manual Trip Lever on Safety Switch to Assure Shutdown during servicing, Full Load Contact Ratings: 7.4 Amp @ 120Vac, 3.7 Amp @ 240Vac, Locked Rotor Contact Ratings: 44.4 Amp @ 120Vac, 22.2 Amp @ 240Vac, Pilot Duty Alarm Load Ratings: 75Va @ 120/240Vac, 25Va @ 24Vac, Resistive Alarm Load Ratings: 1.5 Amp @ 120/240Vac, 3 Amp @ 24Vac, -40-130 Degree Temperature Range

Resideo

R8184G4033

Protectorelay Oil Burner Control, Controls Oil Burner, Oil Valve and the Ignition Transformer in Response to a Call for Heat, 30 Second Safety Switch Timing, With LED for Lockout Indication and Manual Trip Lever on Safety Switch to Assure Shutdown during servicing, Full Load Contact Ratings: 7.4 Amp @ 120Vac, 3.7 Amp @ 240Vac, Locked Rotor Contact Ratings: 44.4 Amp @ 120Vac, 22.2 Amp @ 240Vac, Pilot Duty Alarm Load Ratings: 75Va @ 120/240Vac, 25Va @ 24Vac, Resistive Alarm Load Ratings: 1.5 Amp @

Resideo

R8184G4066

Protectorelay Oil Burner Control, Controls Oil Burner, Oil Valve and the Ignition Transformer in Response to a Call for Heat, 15 Second Safety Switch Timing, With LED for Lockout Indication and Manual Trip Lever on Safety Switch to Assure Shutdown during servicing, Full Load Contact Ratings: 7.4 Amp @ 120Vac, 3.7 Amp @ 240Vac, Locked Rotor Contact Ratings: 44.4 Amp @ 120Vac, 22.2 Amp @ 240Vac, Pilot Duty Alarm Load Ratings: 75Va @ 120/240Vac, 25Va @ 24Vac, Resistive Alarm Load Ratings: 1.5 Amp @ 120/240Vac, 3 Amp @ 24Vac, -40-130 Degree Temperature Range

Resideo

R8184G4082

Protectorelay Oil Burner Control, Controls Oil Burner, Oil Valve and the Ignition Transformer in Response to a Call for Heat, 45 Second Safety Switch Timing, With LED for Lockout Indication and Manual Trip Lever on Safety Switch to Assure Shutdown during servicing, Full Load Contact Ratings: 7.4 Amp @ 120Vac, 3.7 Amp @ 240Vac, Locked Rotor Contact Ratings: 44.4 Amp @ 120Vac, 22.2 Amp @ 240Vac, Pilot Duty Alarm Load Ratings: 75Va @ 120/240Vac, 25Va @ 24Vac, Resistive Alarm Load Ratings: 1.5 Amp @ 120/240Vac, 3 Amp @ 24Vac, -40-130 Degree Temperature Range, Includes Remote Alarm Dry Contacts

Resideo

R8184M1051

Protectorelay Oil Burner Control, Operates the Oil Burner and Oil Valve ( if desired ) in Response to a call for Heat from a Low Voltage Control Circuit, 45 Second Safety Timing Switch, Mounts on a Standard 4"x4" Junction Box, Full Load Contact Ratings: 7.4 Amp @ 120Vac, 3.7 Amp @ 240Vac, Locked Rotor Contact Ratings: 44.4 Amp @ 120Vac, 22.2 Amp @ 240Vac, Includes a 40Va Transformer and Y and G Terminals for Connection of Cooling Equipment

Resideo

R8222B1067

General Purpose Switching Relay, 24Vac Coil Rating, SPDT, Full Load Contact Ratings: 3 Amp @ 480Vac, 6 Amp @ 208/240/277Vac, 12 Amp @ 120Vac, Locker Rotor Contact Rating: 18 Amp @ 480Vac, 35 Amp @ 208/240/277 Vac, 60 Amp @ 120Vac, Resistive Contact Rating: 10 Amp @ 480Vac, 20.8 Amp @ 120/208/240/277Vac, Pilot Duty Ratings: Minimum 3 VA @ 24/120Vac & 480Vac, Maximum: 25 VA @ 24Vac, 125 VA @ 120/240Vac and 480Vac, Resistive: 3 Amp @ 277Vac, Powerpile: ( Normally Open Contacts Only ) 0.25 Amp @ 0.25-12Vdc, 1/4" Quick Connect Terminals, -20-150 Degree Temperature Rating

Resideo

R8222D1014

General Purpose Switching Relay, 24Vac Coil Rating, DPDT, Full Load Contact Ratings: 3 Amp @ 480Vac, 6 Amp @ 208/240/277Vac, 12 Amp @ 120Vac, Locker Rotor Contact Rating: 18 Amp @ 480Vac, 35 Amp @ 208/240/277 Vac, 60 Amp @ 120Vac, Resistive Contact Rating: 10 Amp @ 480Vac, 20.8 Amp @ 120/208/240/277Vac, Pilot Duty Ratings: Minimum 3 VA @ 24/120Vac & 480Vac, Maximum: 25 VA @ 24Vac, 125 VA @ 120/240Vac and 480Vac, Resistive: 3 Amp @ 277Vac, Powerpile: ( Normally Open Contacts Only ) 0.25 Amp @ 0.25-12Vdc, 1/4" Quick Connect Terminals, -20-150 Degree Temperature Rating

Resideo

R8222N1011

General Purpose Switching Relay, 24Vac Coil Rating, DPDT- Pilot Duty, Full Load Contact Ratings: 3 Amp @ 480Vac, 6 Amp @ 208/240/277Vac, 12 Amp @ 120Vac, Locker Rotor Contact Rating: 18 Amp @ 480Vac, 35 Amp @ 208/240/277 Vac, 60 Amp @ 120Vac, Resistive Contact Rating: 10 Amp @ 480Vac, 20.8 Amp @ 120/208/240/277Vac, Pilot Duty Ratings: Minimum 3 VA @ 24/120Vac & 480Vac, Maximum: 25 VA @ 24Vac, 125 VA @ 120/240Vac and 480Vac, Resistive: 3 Amp @ 277Vac, Powerpile: ( Normally Open Contacts Only ) 0.25 Amp @ 0.25-12Vdc, 1/4" Quick Connect Terminals, -20-150 Degree Temperature Rating

Resideo

R8222U1006/B

GenPurpRelay DPST N/O 24v