Danfoss
114N6714
|
R404A, Condensing Unit, 4 HP Rating, -40 Degree Farenheit to -10 Degree Farenheit Evaporating Temperature Range, 7/8" ODF (Sweat) Suction Line, 1/2" ODF (Sweat) Liquid Line, 208-230 Volt 3 Phase 60 Hz Compressor, 230 Volt 1 Phase 60 Hz Fan, Air cooled Condenser, Dual Fan, hermetic Compressor, Electrical Box, Receiver, Dual Pressure control, Fan Cycling Control, UL Listed Certification, (Model LGZC0401UWE300Q )
|
|
|
Danfoss
114N6715
|
R404A, Condensing Unit, 4 HP Rating, -40 Degree Farenheit to -10 Degree Farenheit Evaporating Temperature Range, 7/8" ODF (Sweat) Suction Line, 1/2" ODF (Sweat) Liquid Line, 460 Volt 3 Phase 60 Hz Compressor, 460 Volt 1 Phase 60 Hz Fan, Air cooled Condenser, Dual Fan, hermetic Compressor, Electrical Box, Receiver, Dual Pressure control, Fan Cycling Control, UL Listed Certification, (Model LGZC0401UWE300R )
|
|
|
Danfoss
114N6717
|
R404A, Condensing Unit, 6 HP Rating, -40 Degree Farenheit to -10 Degree Farenheit Evaporating Temperature Range, 1 1/8" ODF (Sweat) Suction Line, 1/2" ODF (Sweat) Liquid Line, 208-230 Volt 3 Phase 60 Hz Compressor, 230 Volt 1 Phase 60 Hz Fan, Air cooled Condenser, Dual Fan, hermetic Compressor, Electrical Box, Receiver, Dual Pressure control, Fan Cycling Control, UL Listed Certification, (Model LGZC0601UWE300Q )
|
|
|
Danfoss
114N6718
|
R404A, Condensing Unit, 6 HP Rating, -40 Degree Farenheit to -10 Degree Farenheit Evaporating Temperature Range, 1 1/8" ODF (Sweat) Suction Line, 1/2" ODF (Sweat) Liquid Line, 460 Volt 3 Phase 60 Hz Compressor, 460 Volt 1 Phase 60 Hz Fan, Air cooled Condenser, Dual Fan, hermetic Compressor, Electrical Box, Receiver, Dual Pressure control, Fan Cycling Control, UL Listed Certification, (Model LGZC0601UWE300R )
|
|
|
Danfoss
114N6720
|
R404A, Condensing Unit, 7 1/2 HP Rating, -40 Degree Farenheit to -10 Degree Farenheit Evaporating Temperature Range, 1 1/8" ODF (Sweat) Suction Line, 1/2" ODF (Sweat) Liquid Line, 208-230 Volt 3 Phase 60 Hz Compressor, 230 Volt 1 Phase 60 Hz Fan, Air cooled Condenser, Dual Fan, hermetic Compressor, Electrical Box, Receiver, Dual Pressure control, Fan Cycling Control, UL Listed Certification, (Model LGZC0751UWE300Q )
|
|
|
Danfoss
114N6721
|
R404A, Condensing Unit, 7 1/2 HP Rating, -40 Degree Farenheit to -10 Degree Farenheit Evaporating Temperature Range, 1 1/8" ODF (Sweat) Suction Line, 1/2" ODF (Sweat) Liquid Line, 460 Volt 3 Phase 60 Hz Compressor, 460 Volt 1 Phase 60 Hz Fan, Air cooled Condenser, Dual Fan, hermetic Compressor, Electrical Box, Receiver, Dual Pressure control, Fan Cycling Control, UL Listed Certification, (Model LGZC0751UWE300R )
|
|
|
Danfoss
114N6725
|
R404A, Condensing Unit, 1 1/2 HP Rating, -40 Degree Farenheit to -10 Degree Farenheit Evaporating Temperature Range, 1/2" ODF (Sweat) Suction Line, 3/8" ODF (Sweat) Liquid Line, 230 Volt 1 Phase 60 Hz Compressor and Fan, Air cooled Condenser, Single Fan, hermetic Compressor, Electrical Box, Receiver, Dual Pressure control, Fan Cycling Control, Filter Drier, Sight Glass, Solenoid Valve with coil, UL Listed Certification, (Model LCZC0151UWF300N )
|
|
|
Danfoss
114N6726
|
R404A, Condensing Unit, 1 1/2 HP Rating, -40 Degree Farenheit to -10 Degree Farenheit Evaporating Temperature Range, 1/2" ODF (Sweat) Suction Line, 3/8" ODF (Sweat) Liquid Line, 208-230 Volt 3 Phase 60 Hz Compressor, 230 Volt 1 Phase 60 Hz Fan, Air cooled Condenser, Single Fan, hermetic Compressor, Electrical Box, Receiver, Dual Pressure control, Fan Cycling Control, Filter Drier, Sight Glass, Solenoid Valve with coil, UL Listed Certification, (Model LCZC0151UWF300Q )
|
|
|
Danfoss
114N6727
|
R404A, Condensing Unit, 1 1/2 HP Rating, -40 Degree Farenheit to -10 Degree Farenheit Evaporating Temperature Range, 1/2" ODF (Sweat) Suction Line, 3/8" ODF (Sweat) Liquid Line, 460 Volt 3 Phase 60 Hz Compressor, 460 Volt 1 Phase 60 Hz Fan, Air cooled Condenser, Single Fan, hermetic Compressor, Electrical Box, Receiver, Dual Pressure control, Fan Cycling Control, Filter Drier, Sight Glass, Solenoid Valve with coil, UL Listed Certification, (Model LCZC0151UWF300R )
|
|
|
Danfoss
114N6729
|
R404A, Condensing Unit, 2 HP Rating, -40 Degree Farenheit to -10 Degree Farenheit Evaporating Temperature Range, 5/8" ODF (Sweat) Suction Line, 3/8" ODF (Sweat) Liquid Line, 230 Volt 1 Phase 60 Hz Compressor and Fan, Air cooled Condenser, Single Fan, hermetic Compressor, Electrical Box, Receiver, Dual Pressure control, Fan Cycling Control, Filter Drier, Sight Glass, Solenoid Valve with coil, UL Listed Certification, (Model LCZC0201UWF300N )
|