Danfoss
077F8798
|
SENSOR, 2%, 2-POLE 3000MM
|
|
|
Danfoss
077Z7010
|
Refrigerator Application, Constant Cut-in Operation Mode, +38 F / +28 F Warm postion Cut-in/Cut-out Temperature Range, +38 F / +19 Middle postion Cut-in/Cut-out Temperature Range, +38 F / +9 F Cold postion Cut-in/Cut-out Temperature Range, Coiled Bulb Sensor type, 39"Capillary Tube Length, Universal Service Thermostat
|
|
|
Danfoss
077Z7011
|
Refrigerator Application, Constant Cut-in Operation Mode, +41 F / +29.5 F Warm postion Cut-in/Cut-out Temperature Range, +41 F / +23.5 F Middle postion Cut-in/Cut-out Temperature Range, +41 F / +17 F Cold postion Cut-in/Cut-out Temperature Range, Straight Sensor Sensor type, 84"Capillary Tube Length, Universal Service Thermostat
|
|
|
Danfoss
077Z7012
|
Refrigerator / Freezer Application, Adaptable Constant Diferrential Operation Mode, +36 F / +26 F Warm postion Cut-in/Cut-out Temperature Range, +21.5 F / +9 F Middle postion Cut-in/Cut-out Temperature Range, +3 F / -14 F Cold postion Cut-in/Cut-out Temperature Range, Straight Sensor Sensor type, 42"Capillary Tube Length, Universal Service Thermostat
|
|
|
Danfoss
077Z7013
|
Refrigerator / Freezer Application, Adaptable Constant Diferrential Operation Mode, +36 F / +26 F Warm postion Cut-in/Cut-out Temperature Range, +21.5 F / +9 F Middle postion Cut-in/Cut-out Temperature Range, +3 F / -14 F Cold postion Cut-in/Cut-out Temperature Range, Straight Sensor Sensor type, 84"Capillary Tube Length, Universal Service Thermostat
|
|
|
Danfoss
077Z7014
|
Low Temperature Freezer Application, Adaptable Constant Diferrential Operation Mode, +16.5 F / 7 F Warm postion Cut-in/Cut-out Temperature Range, +4 F / -7 F Middle postion Cut-in/Cut-out Temperature Range, -11 F / -25.5 F Cold postion Cut-in/Cut-out Temperature Range, Straight Sensor Sensor type, 84"Capillary Tube Length, Universal Service Thermostat
|
|
|
Danfoss
077Z7015
|
Low Temperature Freezer Application, Adaptable Constant Diferrential Operation Mode, +9.5 F / + 3 F Warm postion Cut-in/Cut-out Temperature Range, -3 F / -11 F Middle postion Cut-in/Cut-out Temperature Range, -18.5 F / -29 F Cold postion Cut-in/Cut-out Temperature Range, Straight Sensor Sensor type, 42"Capillary Tube Length, Universal Service Thermostat
|
|
|
Danfoss
077Z7016
|
Low Temperature Freezer Application, Adaptable Constant Diferrential Operation Mode, +9.5 F / + 3 F Warm postion Cut-in/Cut-out Temperature Range, -3 F / -11 F Middle postion Cut-in/Cut-out Temperature Range, -18.5 F / -29 F Cold postion Cut-in/Cut-out Temperature Range, Straight Sensor Sensor type, 84"Capillary Tube Length, Universal Service Thermostat
|
|
|
Danfoss
077Z7017
|
Refrigerator Application, Adaptable Constant Diferrential Operation Mode, +47 F / +36.5 F Warm postion Cut-in/Cut-out Temperature Range, +37.5 F / +25 F Middle postion Cut-in/Cut-out Temperature Range, +25.5 F / +10 F Cold postion Cut-in/Cut-out Temperature Range, Straight Sensor Sensor type, 66"Capillary Tube Length, Universal Service Thermostat
|
|
|
Danfoss
078G5001
|
PRESSURE TRANSMITTER
|